PLT UNABLE TO USE ALL FUEL ABOARD ACFT. MAKES UNSCHEDULED STOP FOR REFUELING. FUEL VALVE UNDER PLT SEAT IS IN OFF POS; WITH NO ACCESS TO IT UNTIL PARKED ON GND.
Synopsis
PLT UNABLE TO USE ALL FUEL ABOARD ACFT. MAKES UNSCHEDULED STOP FOR REFUELING. FUEL VALVE UNDER PLT SEAT IS IN OFF POS; WITH NO ACCESS TO IT UNTIL PARKED ON GND.
Narrative
THE INCIDENT OCCURRED DURING A FLT FROM PHN TO TYS OF APPROX 3 HRS DURATION. AFTER RUNNING EXACTLY 2:20 ON THE MAIN FUEL SUPPLY; WE SELECTED THE AUX FUEL SUPPLY. THE ENG IMMEDIATELY SUFFERED FROM FUEL DEPRIVATION. A SYS CHK PROVIDED NO INDICATION OF THE CAUSE OF THE PROB. THE MAIN FUEL SUPPLY WAS RESELECTED AND THE PROB WAS ELIMINATED. A FUEL CONSUMPTION ANALYSIS INDICATED THAT THE TYS DEST WOULD BE UNACHIEVABLE. I REQUESTED AN IMMEDIATE DEV TO THE NEAREST ARPT (LOZ) TO ELIMINATE THE POTENTIAL FOR FURTHER COMPLICATIONS. THE DEV WAS AUTH AND MADE. THIS ACTION RESULTED IN A SAFE LNDG WITHOUT FURTHER INCIDENT. A THOROUGH ANALYSIS ON THE GND INDICATED THAT AT SOME TIME DURING THIS OR A PRECEDING FLT AN OBJECT OR THE SEAT WHILE BEING INSTALLED BUMPED AND TURNED OFF THE FUEL SUPPLY VALVE TO THE AUX SYS (LOCATED UNDER THE SEAT). WITH THE PROB IDENTED; AN ARPT WITH A MECH AVAILABLE WITHIN 1:15 OF FLYING TIME WE REFUELED THE MAIN FUEL SUPPLY AND PROCEEDED WITHOUT INCIDENT TO AHN. THE MECH ON DUTY AT AHN EXAMINED THE ACFT; CONCURRED WITH OUR DIAGNOSIS AND CERTIFIED THE ACFT AS AIRWORTHY. UPON RETURN TO OUR HOME BASE OF PHN; WE MADE ARRANGEMENTS WITH OUR LCL MAINT SHOP TO INSTALL A PROTECTIVE FLAP OVER THE VALVE TO ELIMINATE THE POTENTIAL FOR THIS HAPPENING AGAIN.
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.