PART 135 BA32 FLC EXPERIENCED HYD FAILURE DURING APCH. MISSED APCH AND DECLARED EMER.
Synopsis
PART 135 BA32 FLC EXPERIENCED HYD FAILURE DURING APCH. MISSED APCH AND DECLARED EMER.
Narrative
DURING DSCNT INTO GSO I NOTICED THAT THE R HYD PUMP PRESSURE WAS ZERO; L PUMP PRESSURE WAS NORMAL. MAIN AND EMER ACCUMULATOR PRESSURE WAS NORMAL. DURING FINAL APCH SEGMENT FLAPS WERE SELECTED TO 10 DEGS; AT WHICH POINT THE L PUMP PRESSURE DROPPED TO ZERO. WE SELECTED GEAR DOWN AND ONLY THE NOSE GEAR SHOWED DOWN AND LOCKED. HYD PUMPS WERE CAVITATING AT THIS TIME AND EMER AND MAIN PRESSURE INDICATIONS REMAINED NORMAL. WE BEGAN MISSED APCH PROCS. ADVISED ATC; DECLARED AN EMER; EVEN THOUGH WE DID NOT FEEL IT WAS AN EMER. AT THIS TIME WE COMPLIED WITH ALL CHKLIST ITEMS AND OUR QRH GUIDELINES FOR HYD PRESSURE/PUMP FAILURES. RETURNED TO GSO AND LANDED UNEVENTFULLY. STOPPED THE ACFT ON RWY 5 TO CHK HANDLING. ACFT PERFORMED NORMAL SO WE CLRED THE ACTIVE RWY AND STOPPED ON THE TXWY; COMPLETED AFTER LNDG CHKLIST AND AGAIN CHKED ACFT TO SEE IF WE COULD CONTINUE TO TAXI. ACFT HANDLED WELL SO WE PROCEED TO THE RAMP AND SHUT DOWN THE ACFT; DEPLANED THE PAX. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: INITIALLY; PUMP FAILURE WAS SUSPECTED SO THIS IS WHY FLC CONTINUED TO OPERATE FLAPS (BA32 EMER HYD SYS DOES NOT ALLOW FLAP RETRACTION). AFTER EMER DECLARED; TWR HANDLED ALL COMS WITH EMER RESPONSE TEAM. A TUG WAS NOT AVAILABLE AT THIS STATION; AND ACFT ARR AT GATE COINCIDED WITH ACCUMULATOR DEPLETION. FOLLOW-UP WITH MAINT REVEALED CHAFING IN R LNDG GEAR BAY DOOR HYD LINE WHICH CAUSED SYS LEAK.
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.