A B747-200 IN CRUISE AT FL330 WITH A DEFERRED AUTO PRESSURE PRESSURIZATION INOP LOST THE CABIN PRESSURE ON THE MANUAL SYS.
Synopsis
A B747-200 IN CRUISE AT FL330 WITH A DEFERRED AUTO PRESSURE PRESSURIZATION INOP LOST THE CABIN PRESSURE ON THE MANUAL SYS.
Narrative
AT ABOUT 7 1/2 HRS INTO THE FLT LAX-NRT; WE EXPERIENCED A FAULT IN THE MANUAL PORTION OF OUR AUTO PRESSURE CONTROLLER; WHICH INITIALLY CAUSED A SLOW TO MEDIUM LOSS OF PRESSURIZATION AT INITIAL CABIN ALT OF APPROX 6500 FT TO OVER 10000 FT CABIN ALT. SO ATTEMPTED TO REMEDY THE RUNAWAY CABIN ALT; BUT INADVERTENTLY OPENED THE OUTFLOW VALVES MORE AND CAUSED CABIN PRESSURE LOSS TO ACCELERATE. CABIN EXCEEDED 14000 FT AND PAX MASKS DROPPED. CREW DONNED OXYGEN MASKS; ESTABLISHED COMS. CAPT ASSISTED SO IN EVALUATING PROB AND DETERMINED SOLUTION TO MANUALLY CLOSE OUTFLOW VALVES TO RE-ESTABLISH CABIN ALT BELOW 10000 FT CABIN ALT. CAPT REACHED FOR RED BORDERED CHKLIST; AS SO OPENED COCKPIT OPERATING MANUAL TO 'RAPID DEPRESSURIZATION' CHKLIST AND FOLLOWED THROUGH WITH THE PROC. CABIN ALT CONTROL WAS REESTABLISHED MANUALLY. CABIN ALT RETURNED TO APPROX 6500 FT. PAX OXYGEN SYS WAS ATTEMPTED TO RESET; BUT AFTER A SHORT WHILE CAPT NOTICED THAT PAX OXYGEN WAS LEAKING. CAPT CONTACTED DISPATCH CTL IN MSP VIA COMMERCIAL RADIO PHONE PATCH AND DISCUSSED DSNDING TO LOWER ALT OF FL240 FOR REMAINDER OF FLT AT LONG RANGE CRUISE SPD. FUEL CALCULATIONS WERE VERIFIED THROUGH DISPATCH; AND FLT DSNDED TO FL240 FOR LAST 2 HRS OF THE FLT PRIOR TO DSCNT FOR NORMAL APCH AND LNDG AT TOKYO NARITA; JAPAN. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: THE RPTR STATED THE ACFT AFTER 7.5 HRS INTO THE FLT WAS EXPERIENCING A SLOW TO MEDIUM CABIN PRESSURIZATION LOSS AND EXPERIENCING PRESSURE 'BUMPS' CAUSED BY CYCLING OF THE CARGO HEAT SYS. THE RPTR SAID THE FE IN ATTEMPTING TO CTL THE CABIN PRESSURE MANUALLY INADVERTENTLY OPENED THE OUTFLOW VALVES AND THE CABIN PRESSURE WAS LOST. THE RPTR STATED THE PRESSURE WAS REGAINED BUT NOT BEFORE THE OXYGEN MASKS WERE DEPLOYED. THE RPTR SAID THIS ACFT WAS DISPATCHED WITH THE CABIN PRESSURE AUTO CTL SYS DEFERRED AS INOP PER THE MEL. THE RPTR STATED THIS SYS SHOULD NOT BE DEFERRED ON LONG OVERWATER FLTS. THE RPTR SAID MAINT REPLACED THE CABIN PRESSURE CONTROLLER.
More incidents for this aircraft family →
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.