A B767-200 IN CLB AT 10000 FT DECLARED AN EMER AND DIVERTED DUE TO MULTIPLE INST FAILURES CAUSED BY INCORRECT DEFERRAL OF THE FORWARD EQUIP COOLING SYS AUTO MODE.

Date: 2002-05 · Aircraft: B767 Undifferentiated or Other Model · Phase: climb

Anomalies: aircraft-equipment-problem-critical|deviation-discrepancy-procedural-far|deviation-discrepancy-procedural-mel-cdl|deviation-discrepancy-procedural-published-material-policy|deviation-discrepancy-procedural-maintenance

Synopsis

A B767-200 IN CLB AT 10000 FT DECLARED AN EMER AND DIVERTED DUE TO MULTIPLE INST FAILURES CAUSED BY INCORRECT DEFERRAL OF THE FORWARD EQUIP COOLING SYS AUTO MODE.

Narrative

ACFT X WAS BEING DISPATCHED WITH THE AUTO MODE OF THE FORWARD EQUIP COOLING SYS INOP. THE MEL STATED THAT DEP IN THE STANDBY MODE WAS PERMISSIBLE. AFTER TKOF; NUMEROUS ELECTRONIC FLT INST FAILURES AND ANOMALIES WERE OBSERVED; INCLUDING ADI; HSI RADAR; AUTOPLT MALFUNCTIONS; ETC. OUR RTE TO ZZZ1 INCLUDED SOME CONVECTIVE WX AND THE FORECAST WX FOR ZZZ1 HAD RECENTLY CHANGED AND REQUIRED US TO ADD AN ALTERNATE. WITH THE MULTIPLE INST FAILURES AND UNSUCCESSFUL INITIAL ATTEMPTS TO RESTORE THE INSTRUMENTATION; AS WELL AS THE WX WE WERE LIKELY TO ENCOUNTER; I ELECTED TO RETURN TO ZZZ. WE PRESUMED THAT THE INST FAILURES/INDICATION ANOMALIES WERE ASSOCIATED WITH THE EQUIP COOLING DEFERRAL AT ORIGINAL DISPATCH. WE WERE FORTUNATE TO HAVE A TRAINING CAPT FROM THE TRAINING CTR TO ASSIST WITH PROB ASSESSMENT AND COM. AN EMER WAS DECLARED IN ORDER TO EXPEDITE HANDLING AT ZZZ. WE ULTIMATELY RE-ESTABLISHED THE COOLING SYS TEMPORARILY AND LANDED THE ACFT UNEVENTFULLY AT ZZZ. I AM A BIT SURPRISED THAT WE EXPERIENCED THE EQUIP FAILURES DESPITE THE MEL DEFERRAL. IT WAS NOT A HOT DAY IN ZZZ; YET THE MEL ALLOWS FOR OP WITH THE AUTOMODE OF THE EQUIP COOLING SYS TO BE INOP.

More incidents for this aircraft family →