A FALCON 900EX WAS DISPATCHED ON A POSITIONING FLT IN NON COMPLIANCE WITH A REQUIRED INSPECTION ITEM NOT ACCOMPLISHED AND UNCORRECTED RPTS ON THE STANDBY ALTIMETER AND AIRSPD INDICATOR.
Synopsis
A FALCON 900EX WAS DISPATCHED ON A POSITIONING FLT IN NON COMPLIANCE WITH A REQUIRED INSPECTION ITEM NOT ACCOMPLISHED AND UNCORRECTED RPTS ON THE STANDBY ALTIMETER AND AIRSPD INDICATOR.
Narrative
ROUTINE PAPERWORK SURVEILLANCE NOTICED THAT RII INSPECTION SIGN-OFF WAS NOT COMPLETED (PER FAR 135 REGS ON A 10 OR MORE SEAT ACFT). CONTACTED THE REPAIR STATION THAT PERFORMED THE INSPECTIONS TO ADDRESS THE RII INSPECTION STATUS VIA THEIR WORK ORDER SYS. DURING THIS FOLLOW-UP; GAINED INFO THAT THE STANDBY ALTIMETER AND STANDBY AIRSPD INDICATOR HAD FAILED (OUT OF TOLERANCE) THEIR 24-MONTH CALIBRATION CHK. THE REPAIR STATION INFORMED FBO X THAT THEY HAD PRESENTED THIS INFO TO THE MAINT TECHNICIAN REPRESENTING AND RESPONSIBLE FOR THAT ACFT. FURTHER INVESTIGATION REVEALED THAT THE TECHNICIAN HAD FAILED TO CORRECT THE DISCREPANCIES WITH THE STANDBY ALTIMETER AND STANDBY AIRSPD INDICATOR AND RELEASED THE ACFT TO SVC FOR A PART 91 REPOS FLT. FBO X HAS TAKEN THE FOLLOWING ACTION IN RESPONSE TO THIS INCIDENT: 1) GENERAL MAINT MANUAL IS BEING REVISED TO DIRECT ALL THIRD PARTY MAINT LOG ENTRIES TO BE REVIEWED BY EITHER THE DIRECTOR OF MAINT OR DIRECTOR OF QUALITY ASSURANCE PRIOR TO RELEASING THE ACFT TO SVC. 2) THE RESPONSIBLE TECHNICIAN WAS REMOVED FROM THE POS OF MANAGING THAT OR ANY OTHER ACFT OPERATED BY FBO X.
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.