AN AIRBUS A319 FLIGHT CREW WAS DIRECTED BY MAINT CONTROL TO TURN OFF IDG-1 AFTER REPORTING A LEFT OUTBOARD FUEL TEMP EXCEEDED TKOF LIMITS. MAINT CONTROLLER LATER DENIED DIRECTING CREW TO TURN OFF IDG.

Date: 2007-08 · Aircraft: A319 · Phase: taxi

Anomalies: aircraft-equipment-problem-critical

Synopsis

AN AIRBUS A319 FLIGHT CREW WAS DIRECTED BY MAINT CONTROL TO TURN OFF IDG-1 AFTER REPORTING A LEFT OUTBOARD FUEL TEMP EXCEEDED TKOF LIMITS. MAINT CONTROLLER LATER DENIED DIRECTING CREW TO TURN OFF IDG.

Narrative

ACFT ECAM CAUTION THAT L OUTBOARD FUEL TEMP WAS 58 DEGS C; LIMIT FOR TKOF IS 54 DEGS C. FO CALLED MAINT CTL; CTLR SAID TO 'TURN-OFF THE IDG1.' FO TELLS ME; I STOP THE ACFT (PARKING BRAKE SET); I ASKED THE FO TO VERIFY WITH MAINT CTL THE REQUESTED ACTION WHILE I LISTENED TO THE RADIO COM. BOTH OF US HEARD THE MAINT CTLR SAY TO 'TURN-OFF THE IDG1.' AFTER THE CONFIRMATION; WE TURNED OFF IDG1. AFTER ARRIVING AT THE GATE; I MADE AN ENTRY IN THE LOGBOOK THAT MAINT CTL HAD US TURN OFF THE IDG1. WHEN I CALLED MAINT CTL TO GET THE CTLR'S NUMBER; HE REFUSED TO GIVE IT TO ME. HE THEN TOLD ME THAT WE HAD 'MISINTERPED HIS INSTRUCTIONS' AND 'THAT HE COULD PROVE IT WITH THE RECORDING.' I CONTACTED THE CHIEF PLT'S OFFICE AND EXPLAINED THE SITUATION. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: REPORTER STATED WHEN THE MAINT CONTROLLER DIRECTED THEM TO TURN OFF THE 'IDG' THE SECOND TIME; THAT'S JUST WHAT THEY DID. THIS SWITCH ACTUALLY DISCONNECTS THE 'IDG.' HE DOES NOT KNOW WHAT THE FIX WAS FOR THE ORIGINAL HIGH FUEL TEMP PROBLEM. REPORTER ALSO FEELS THE CONTROLLER MAY HAVE LIMITED EXPERIENCE OR FAMILIARITY WITH THE AIRBUS ELECTRICAL SYSTEM.

More incidents for this aircraft family →

Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.