A B767-400 R RECIRCULATION FAN FAILED IN FLT GIVING OFF AN OZONE LIKE SMELL. THE FLT CONTINUED TO ITS DEST.

Date: 2008-06 · Aircraft: B767-400 and 400 ER · Phase: cruise

Anomalies: aircraft-equipment-problem-less-severe

Synopsis

A B767-400 R RECIRCULATION FAN FAILED IN FLT GIVING OFF AN OZONE LIKE SMELL. THE FLT CONTINUED TO ITS DEST.

Narrative

FLT WAS ENRTE FROM ZZZ TO ZZZ1. SOMEWHERE NEAR ZZZ2 AN OZONE LIKE ODOR WAS DETECTED ON THE FLT DECK AND SHORTLY THEREAFTER RPTED FROM THE CABIN. THERE WERE NO ABNORMAL INST INDICATIONS AND THERE WAS NO SMOKE PRESENT. WE ASKED THE FLT ATTENDANTS TO CHK AROUND THE CABIN; AND SPECIFICALLY THE GALLEYS AND INFLT ENTERTAINMENT SYS; FOR A SOURCE. NONE WAS DETECTED; AND THE ODOR SOON DISSIPATED. WE CONTACTED THE ACR MAINT COORDINATOR AND OUR DISPATCHER ON COMPANY RADIO AND DISCUSSED ANY POSSIBLE ACTION SHOULD THE ODOR RECUR; INCLUDING POSSIBLE DIVERSION FIELDS. NEAR THE END OF THIS DISCUSSION THE ODOR DID RETURN; THIS TIME WITH A 'R RECIRCULATION FAN' EICAS MESSAGE. THE QRH HAS NO SPECIFIC PROCS FOR THIS MESSAGE; ONLY THE INFO THAT THE MESSAGE INDICATED THE FAN WAS INOP. WE CONCLUDED THAT THE R RECIRCULATION FAN HAD FAILED. THE ODOR AGAIN DISSIPATED; AND WE DEEMED THE PROB WAS POSITIVELY IDENTED AND ISOLATED. AS PRECAUTIONS AGAINST ANY FURTHER RECURRENCE OR ESCALATION; WE CROSS REFERENCED THE QRH PROC 'SMOKE OR FUMES AIR CONDITIONING' AND THE PLT HANDBOOK CONCERNING CHKLIST PHILOSOPHY IN THIS TYPE OF EVENT. WE ALSO CALLED THE THIRD CREW MEMBER (ANOTHER CAPT) FORWARD FROM HIS BREAK TO CONSULT. WE CONCLUDED IT WAS SAFE AND PRUDENT FOR THE FLT TO PROCEED TO ZZZ1 AND HAD NO FURTHER PROBS ENRTE.

More incidents for this aircraft family →

Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.