SO DISAGREES WITH HIS CAPT OVER AN ABNORMAL PROC.

Date: 1994-08 · Aircraft: B727-200 · Phase: initial_climb

Anomalies: aircraft-equipment-problem-less-severe

Synopsis

SO DISAGREES WITH HIS CAPT OVER AN ABNORMAL PROC.

Narrative

SHORTLY AFTER TKOF WE LOST THE ENTIRE 'A' HYD SYS; ONE OF 2 MAIN SYSTEMS ON THE ACFT. (THERE IS ALSO A SMALLER LIMITED 'STANDBY' SYS). AFTER CONSULTING WITH OUR MAINT CTL AND OUR ONBOARD MANUALS WE ELECTED TO CONTINUE TO OUR DEST OF MSP. IN COMPLIANCE WITH OUR EMER PROCS; WE BEGAN TO PREPARE THE ACFT FOR A SINGLE OPERATING HYD SYS APCH AS WE NEARED MSP. ONE OF THE ITEMS WE HAD TO ACCOMPLISH WAS THE LOWERING OF THE FLAPS WITH AN ALTERNATE ELECTRICAL MOTOR (INSTEAD OF HYD). ON FINAL APCH THE MOTOR FOR THE OUTBOARD FLAPS FAILED; LEAVING US WITH JUST THE INBOARD FLAPS. AT THIS POINT WE HAD TO ACCOMPLISH A NEW SEPARATE PROC FOR THE FAILURE OF THIS SYS WHICH NECESSITATED GOING INTO A HOLDING PATTERN; AND BURNING EXTRA FUEL. IN RETROSPECT; I FEEL IT MAY HAVE BEEN BETTER TO RETURN TO RNO AFTER THE FIRST FAILURE OF THE HYD SYS. AFTER ANY MAJOR SYS' DEGRADATION THE POSSIBILITY ALWAYS EXISTS FOR A SECOND PROB TO ARISE. WHEN THIS OCCURS WITH A MINIMUM FUEL STATE; YOUR OPTIONS FOR DEALING WITH A SECOND EMER MAY SUDDENLY BECOME VERY LIMITED.

More incidents for this aircraft family →