No fatalities

Smoke in Cabin Prompts Emergency Evacuation of American Eagle Flight 3773 (N502AE)

Peoria, IL, United States

On July 19, 2012, a BOMBARDIER INC CL-600-2C10 (registration N502AE) operated by AMERICAN EAGLE AIRLINES, INC. was involved in an aviation accident near Peoria, IL. No fatalities were reported. Investigators recorded the probable cause as: The emergency ground egress during which a passenger broke her ankle. Contributing to the accident was the failure of the environmental system, which allowed smoke from a nearby house fire to enter the airplane. This summary draws on records from NTSB; 12 related events involving the same aircraft type or operator are linked below.

SourcesNTSBPrimary reportUpdated 2026-08-03Data APIEditorial standards

On July 18, 2012, American Eagle Flight 3773 diverted to Peoria due to smoke detected on approach. An emergency evacuation was conducted; one passenger sustained a broken ankle. No fire source was found, but the aircraft overflew a large house fire.

Incident Overview

On July 18, 2012, at approximately 2200 central daylight time, a Bombardier CL-600-2C10 airplane, registration N502AE, operating as American Eagle Flight 3773, diverted to the General Downing-Peoria International Airport (KPIA), Peoria, Illinois, due to weather. The flight had originally departed Denver International Airport (KDEN) at about 1855 mountain daylight time, destined for Chicago O'Hare International Airport (KORD). While on a three-mile final approach to KPIA, the crew detected smoke in the airplane. After landing, the crew directed an emergency ground egress. The two over-wing exits and the main entrance door were used for the evacuation.

Occupant Injuries

The two pilots, two cabin crew members, and 52 passengers were uninjured. One passenger sustained a serious injury—a broken ankle—during the egress.

Aircraft Examination

Post-landing examination revealed no obvious source of the smoke and no damage to the airplane. The airplane was operating with a single environmental pack, as permitted by the minimum equipment list. The remaining environmental pack failed while the airplane was on final approach, causing the system to revert to allowing ambient air to enter the cabin. No sources of fire were located within the airplane. However, along the approach path to the airport, the airplane overflew a large house fire.

Operational Conditions

The flight was conducted under the provisions of Code of Federal Regulations Part 121 as a scheduled passenger flight. Night visual meteorological conditions prevailed, and the flight was operated on an instrument flight rules flight plan.

Contributing factors

Causes

Passenger

Other contributing factors

Cooling sys (air/vapor cycle) — FailureDecision related to condition