No fatalities

Nose-Over After Landing in Gusty Crosswind

Greenville, ME, United States

On March 2, 2017, a CESSNA 172 B was involved in an aviation accident near Greenville, ME. No fatalities were reported. Investigators recorded the probable cause as: The pilot's failure to maintain directional control while taxiing in gusting crosswind conditions. This summary draws on records from NTSB; 12 related events involving the same aircraft type or operator are linked below.

SourcesNTSBPrimary reportUpdated 2026-08-03Data APIEditorial standards

A pilot reported that after landing in gusting headwind, turning onto an intersecting runway exposed the aircraft to gusting crosswind. While taxiing, the left wing lifted, veering right and nosing over on snow-covered terrain, resulting in substantial damage to the vertical stabilizer.

Accident Overview

The pilot reported that the accident occurred after a normal landing in gusting headwind conditions. Following the landing, he turned onto an intersecting runway, which introduced gusting crosswind conditions. The pilot adjusted the flight controls to counteract the crosswind. However, after traveling about 150 feet along the runway, the left wing of the airplane lifted. This caused the airplane to veer to the right and subsequently nose over. The terrain was covered with snow at the time.

Damage and Mechanical Condition

As a result of the nose-over, the vertical stabilizer incurred substantial damage. The pilot stated that there were no preaccident mechanical malfunctions or failures that would have prevented normal operation.

Meteorological Information

The automated weather observation station at the airport recorded, near the time of the accident, wind direction 300 degrees at 13 knots with gusts to 28 knots. The pilot reported that he was taxiing on runway 3.

Contributing factors

Causes

PilotDirectional control — Not attained/maintained

Other contributing factors

Ability to respond/compensateContributed to outcome

Frequently asked questions

What happened in the 2 Mar 2017 CESSNA 172 B accident near Greenville, ME?

A pilot reported that after landing in gusting headwind, turning onto an intersecting runway exposed the aircraft to gusting crosswind. While taxiing, the left wing lifted, veering right and nosing over on snow-covered terrain, resulting in substantial damage to the vertical stabilizer.

Were there any fatalities in the 2 Mar 2017 CESSNA 172 B accident?

No fatalities were recorded in this accident.

What aircraft was involved and where did it happen?

The accident on 2 Mar 2017 involved a CESSNA 172 B, at Greenville, ME.

What was the probable cause of the accident?

The pilot's failure to maintain directional control while taxiing in gusting crosswind conditions.