Casualties unknown

1984-01-18: Cessna 310Q (N628AS) — Corporate Air Inc — Casper, WY

Casper, WY, US

On January 18, 1984, a Cessna 310Q (registration N628AS) operated by Corporate Air Inc was involved in an aviation accident near Casper, WY. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 1781061362Data APIEditorial standards

A pilot continued a flight despite a mechanic's recommendation to repair, leaving a fuel selector in cross-feed position. Both engines lost power during descent, resulting in a forced landing on uneven terrain and gear collapse. Fuel starvation was identified.

Incident Overview

During a multi-leg flight, a pilot faced difficulties with the right fuel selector. According to the pilot, he was informed that the right auxiliary fuel pump was inoperative and that to prime and start the right engine, he had to position the right fuel selector to cross-feed. On the first two legs, he used this procedure but noted that the right fuel selector was hard to move.

Maintenance and Decision

While starting for the third leg, the pilot was unable to move the right fuel selector to cross-feed. He obtained assistance from a mechanic, who manually repositioned the selector in the wing. The mechanic recommended repairing the aircraft before further flight. However, the pilot decided to leave the right selector in cross-feed and continue with the flight.

In-Flight Fuel Situation

During the flight, both engines consumed fuel from the left side. During descent, both engines lost power. The pilot subsequently performed a forced landing on uneven terrain, and the landing gear collapsed after crossing a depression.

Post-Accident Examination

An examination revealed that the left main and left auxiliary tanks were at or near empty. The nacelle tank and right auxiliary tank were full, and the right main tank was ruptured. The pilot was unaware that he could have cross-fed fuel from the right tanks to the left engine. Additionally, the fuel system design required that fuel from the nacelle tank be transferred to the main tank before use. Unused fuel and vapor from the engines were routed to the respective main tanks.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001214X38551. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.