1997-12 · NASA ASRS report 388027
AN ACR B727 FLC DISCOVER THAT THEIR STANDBY ATTITUDE INDICATOR DID NOT OPERATE WHEN THE PRIMARY ENG AND APU GENERATORS WERE DISCONNECTED. THE STANDBY INSTS WOULD OPERATE IF THE STANDBY PWR SWITCH WAS SELECTED TO STANDBY. HOWEVER; THIS PROC APPEARS TO BE CONTRARY TO FAR PART 121 PT 305(K)(4).
ON DEC/THU/97; AT APPROX XA50 LCL EST; AS A RESULT OF AN FAA/COMPANY REQUIRED FE PREFLT CHKLIST; I OBSERVED THAT THE STANDBY ATTITUDE INDICATOR PWR INTERP WARNING FLAG CAME INTO VIEW WHILE SIMULATING THE LOSS OF ALL GENERATOR PWR 'ESSENTIAL AND STANDBY PWR...CHK.' THIS APPEARED TO BE AN ABNORMAL STANDBY ATTITUDE INDICATOR SYS RESPONSE. AVIONICS MAINT WAS REQUESTED. AFTER EXPLAINING THE SIT; THE MAINT TECHNICIAN RESPONDED THAT THIS CURRENT STANDBY ATTITUDE INDICATOR SYS CONFIGN WAS NORMAL AND AUTH AS THE RESULT OF AN ENGINEERING ORDER. NEITHER THE AUTHOR; NOR THE CONTENTS OF THIS ENGINEERING ORDER WERE REVEALED OR SPECIFIED. SINCE I; NOR MY CREW; HAD NO OTHER DOCUMENTATION TO SUBSTANTIATE A REJECTION OF THIS EXPLANATION; WE DEPARTED INDIANAPOLIS AS SCHEDULED. UPON OUR ARR IN PHILADELPHIA; THE CAPT SECURED A COPY OF FAR PART 121. THE CAPT THEN CONTACTED THE CHIEF PLT AND APPRISED HIM OF THE APPARENT NON COMPLIANCE OF THIS ACFT STANDBY ATTITUDE INDICATOR SYS WITH FAR PART 121.305(K)(4) AND HIS CONCERN ABOUT THE LEGALITY OF OUR PERFORMING AS CREW MEMBERS ON THE RETURN FLT TO INDIANAPOLIS THAT EVENING. THE CHIEF PLT AGREED. THAT DISCUSSION INCLUDED THE FACT THAT THERE WAS AN ADDITIONAL 6-7 ACFT THAT WERE AFFECTED SIMILARLY BY THIS ENGINEERING ORDER AND SIMILARLY CONFIGURED. THE CAPT ALSO INFORMED THE CHIEF PLT THAT HE WOULD DISCUSS THE SIT WITH ME AND THE FO. LATER THAT AFTERNOON; WE INFORMED SCHEDULING THAT WE WOULD NOT BE ABLE TO FLY THE TRIP BACK TO INDIANAPOLIS WHILE THE ACFT STANDBY ATTITUDE INDICATOR SYS WAS CONFIGURED AS IT WAS. AT APPROX XX30L; THE CAPT WAS CONTACTED BY THE VICE PRESIDENT OF FLT OPS. IT WAS AT THIS TIME THAT VICE PRESIDENT OF FLT OPS INFORMED US THAT THE ACFT WAS LEGAL TO FLY. I INFORMED HIM THAT BASED ON THE INFO NOW AVAILABLE TO US; THAT I BELIEVED THAT THE ACFT WAS NOT LEGAL TO FLY AND THAT IF IT WERE; AS HE AND THE VICE PRESIDENT OF MAINT CLAIMED; THAT THERE WAS NO REASON THAT A WRITTEN STATEMENT COULD NOT BE PROVIDED PRIOR TO THE FLT. THE VICE PRESIDENT OF FLT OPS DENIED THIS REQUEST. HE THEN DIRECTLY ASKED ME FOR MY DECISION; WITHIN THE NEXT 30 SECONDS; IF I WERE GOING TO BE THE FE ON THE RETURN TRIP. I RESPONDED; 'THAT UNLESS I WAS PROVIDED WITH A WRITTEN STATEMENT THAT THE ACFT WAS LEGAL TO FLY AS CURRENTLY CONFIGURED; THAT I WOULD NOT BE THE FE ON THE FLT TO INDIANAPOLIS.' TO THE BEST OF MY KNOWLEDGE THE CAPT AND FO RESPONDED SIMILARLY. SOME TIME SHORTLY AFTER THIS DISCUSSION; THE CAPT RECEIVED A PHONE CALL FROM VICE PRESIDENT OF FLT OPS INFORMING HIM THAT A WRITTEN STATEMENT; AS WE REQUESTED; WOULD BE INCLUDED IN THE DISPATCH PAPERWORK. THE STATEMENT WAS INCLUDED AND WE LEFT PHILADELPHIA AS SCHEDULED. UPON ARR AT INDIANAPOLIS ON FRI MORNING AT APPROX XX00L WE DISCOVERED THAT THIS STATEMENT WAS POSTED THROUGHOUT THE PLT LOUNGE AS A NOTICE TO ALL OTHER CREW MEMBERS. HOWEVER; I STILL RETAIN CONCERN ABOUT THE DISCREPANCY BTWN THE FACT THAT THE CHIEF PLT AGREED EARLY IN THE DAY THAT THE ACFT APPEARED TO BE ILLEGAL TO FLY; AND THEN ONLY HRS LATER THE VICE PRESIDENT OF FLT OPS AND VICE PRESIDENT OF MAINT CLAIMING THAT IT WAS LEGAL TO FLY. I HAVE STILL YET TO RECEIVE ANY FURTHER INFO SUBSTANTIATING THAT THE STANDBY ATTITUDE INDICATOR CONFIGN WAS LEGAL. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: THE RPTR WAS THE SO ON A B727-100 FREIGHTER WHEN HE DISCOVERED THAT THE STANDBY ATTITUDE INDICATOR WOULD NOT OPERATE WHEN THE ENG AND AUX PWR UNIT GENERATORS WERE DISCONNECTED. AFTER INFORMING MAINT THEY WERE SHOWN THAT THE INDICATOR WOULD OPERATE WHEN THE STANDBY PWR SELECTOR WAS SWITCHED TO THE STANDBY POS. THIS IS; IN THE RPTR'S OPINION; CONTRARY TO THE REQUIREMENTS OF THE REGS BECAUSE THE FLC IS REQUIRED TO MAKE A SELECTION AFTER AN ELECTRICAL FAILURE. THIS CHANGE IN THE ACFT'S OP CAME ABOUT AFTER A MAJOR MODIFICATION BY THE RPTR'S COMPANY. IN THE PAST; THE STANDBY INSTS OPERATED USING DC PWR FROM THE BATTERY BUS. THE AIRLINE REMOVED THE OLD DC POWERED INSTS AND REPLACED THEM WITH AC POWERED INSTS THAT OPERATE FROM AC PWR PRODUCED BY THE STANDBY INVERTER; ACCORDING TO THE RPTR. THEREFORE; IF TRUE; THE SO MUST SELECT THE STANDBY PWR SWITCH TO THE STANDBY POS. THE SO SAID THAT THE COMPANY CLAIMS TO HAVE AN ENGINEERING CHANGE ORDER; BUT HAS NOT SHOWN IT TO THE FLC. THE RPTR IS AFRAID THAT; ALTHOUGH THE VICE PRESIDENT OF FLT OPS SENT THEM A LETTER AUTHORIZING THEM TO OPERATE THE ACFT; THEY STILL MAY BE HELD IN VIOLATION OF THE REG. FURTHER; HE IS CONCERNED WITH THE SAFETY OF OPERATING A MIXED FLEET OF B727S THAT HAVE DIFFERENT LOCATIONS FOR THE STANDBY SELECTORS AND THAT HAVE THE SELECTIONS IN DIFFERENT LOCATIONS ON THE SWITCHES.
More incidents for this aircraft family
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.
Loading the flight search…
Pick an aircraft model — Boeing 737, Airbus A320, A380, Boeing 787 Dreamliner and more — enter your origin airport, and FlightFinder shows every route that plane flies from there with live fares.
We support Boeing 737/747/757/767/777/787, the full Airbus A220/A319/A320/A321/A330/A340/A350/A380 family, Embraer E170/E175/E190/E195, Bombardier CRJ and Dash 8, and the ATR 42/72 turboprops.
Search and schedules are free. Pro ($4.99/month, $39/year, or $99 one-time lifetime) unlocks the enriched flight card — on-time stats, CO₂ per passenger, amenities, live gate & weather — plus My Trips with push alerts.
Live schedules come from Amadeus, AeroDataBox and Travelpayouts. Observed routes (which aircraft actually flew a given city pair) are crowdsourced from adsb.lol ADS-B data under the Open Database License.