2007-03 · NASA ASRS report 733318
MD88 FLT CREW EXPERIENCES MULTIPLE GENERATOR MALFUNCTIONS DURING INITIAL CLB WHICH RESULT IN LOST COM AND NAV FAILURES. PWR IS RESTORED BY STARTING APU AND SHUTTING DOWN BOTH GENERATORS.
PUSHBACK; ENG START; TAXI AND TKOF WERE NORMAL. WE WERE INITIALLY ASSIGNED RWY HDG. THE FO WAS THE PF. AS WE CLBED THROUGH ROUGHLY 1100 FT AND JUST AFTER WE STARTED TO CLEAN UP THE ACFT AND WERE GIVEN A R TURN TO HDG 340 DEGS; BOTH GENERATORS BEGAN TO SIMULTANEOUSLY CYCLE ON AND OFF. THE GENERATORS CYCLED ON AND OFF ABOUT 1 1/2 TO 2 TIMES EVERY SECOND. AS EACH CYCLE OCCURRED THERE WERE RELATIVELY LOUD THUMPS WHICH TO ME SOUNDED LIKE RELAYS OPENING AND CLOSING. ALSO; AS EACH CYCLE OCCURRED THE 2 CRT SCREENS IN FRONT OF ME WOULD BLANK AND THE INSTS WOULD JUMP WHICH MADE USING THE INSTS TO FLY NEARLY IMPOSSIBLE. WE TRIED SEVERAL TIMES TO COMMUNICATE WITH DEP CTL WITHOUT SUCCESS. WE XFERRED ACFT CTL TO ME; THE CAPT; THINKING THAT IF WE LOST ALL AC PWR THAT MY STANDBY INSTS WOULD AT LEAST GIVE US SOME REF TO FLY. THE FO ALERTLY SUGGESTED STARTING THE APU; WHICH WE DID IMMEDIATELY. AS THE APU WAS STARTING WE CONTINUED ATTEMPTING TO CONTACT DEP CTL. THE RADIO WOULD CUT IN AND OUT AS THE GENERATORS CYCLED MAKING COMS IMPOSSIBLE. WE WERE IN A VERY; VERY SLOW R-HAND TURN TO HDG 340 DEGS. WHEN THE APU FINALLY STARTED (ROUGHLY 60 SECONDS) THE FO BROUGHT IT ON LINE TO PWR THE ACFT. HE ALSO DISENGAGED BOTH ACFT GENERATORS. THE ACFT WAS NOW FULLY FUNCTIONAL ON APU PWR. WE CONTACTED DEP CTL AND THE CTLR SEEMED A LITTLE UPSET THAT WE WEREN'T YET ON OUR ASSIGNED HDG OF 340 DEGS. WE EXPLAINED WHAT HAD HAPPENED AND HE IMMEDIATELY BEGAN TO ASSIST US. WE DECLARED AN EMER BECAUSE WE DIDN'T KNOW HOW LONG THE APU WOULD PWR THE AC BUSES AND WANTED TO GET THE ACFT ON THE GND. WE WOUND UP GETTING VECTORS FOR AN APCH TO RWY 10. AS WE WERE BEING VECTORED THE FO RAN THE AC PWR INTERMITTENT CHKLIST. I SPOKE WITH THE FLT ATTENDANTS AND MADE A PA TO THE PAX. THE APCH AND LNDG WERE WITHOUT INCIDENT. AFTER THE FIRE TRUCKS LOOKED US OVER WE TAXIED TO THE GATE AND DEPLANED THE PAX. I DON'T KNOW IF WE EVER CAME 'CLOSE' TO ANY OTHER ACFT DUE TO OUR MUCH SLOWER THAN NORMAL R-HAND TURN AFTER TKOF. WE KNEW WE NEEDED TO MAKE A R-HAND TURN BUT OUR INSTS WERE UNUSABLE AT THE TIME. ASKING FOR NO GYRO VECTORS WOULDN'T HAVE WORKED BECAUSE WE COULDN'T COMMUNICATE WITH DEP CTL. IN HINDSIGHT I COULD HAVE SQUAWKED CODE 7600 OR 7700 BUT I'M NOT ENTIRELY SURE THAT WOULD HAVE WORKED EITHER DUE TO THE PWR CYCLING ON AND OFF. ALL IN ALL I WOULD AY THAT WE WERE FORTUNATE THAT THIS SIT OCCURRED DURING DAYLIGHT VMC CONDITIONS. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: RPTR ADVISED THE FLT WAS CANCELED AND THE FLT CREW LAID OVER AND RETURNED THE FOLLOWING DAY TO FLY THE REPAIRED ACFT. THE LOGBOOK SHOWED ONLY THAT THE R GENERATOR WAS REPLACED. RPTR HAD NO INFO REGARDING HOW THE 1 GENERATOR HAD CAUSED THE APPARENT MULTIPLE GENERATOR DISRUPTION THEY HAD EXPERIENCED. THE ACFT OPERATED NORMALLY ON THE SUBSEQUENT FLTS.
Source: NASA Aviation Safety Reporting System (public domain). Reports are voluntary submissions and are not verified by NASA.
Loading the flight search…
Pick an aircraft model — Boeing 737, Airbus A320, A380, Boeing 787 Dreamliner and more — enter your origin airport, and FlightFinder shows every route that plane flies from there with live fares.
We support Boeing 737/747/757/767/777/787, the full Airbus A220/A319/A320/A321/A330/A340/A350/A380 family, Embraer E170/E175/E190/E195, Bombardier CRJ and Dash 8, and the ATR 42/72 turboprops.
Search and schedules are free. Pro ($4.99/month, $39/year, or $99 one-time lifetime) unlocks the enriched flight card — on-time stats, CO₂ per passenger, amenities, live gate & weather — plus My Trips with push alerts.
Live schedules come from Amadeus, AeroDataBox and Travelpayouts. Observed routes (which aircraft actually flew a given city pair) are crowdsourced from adsb.lol ADS-B data under the Open Database License.