No fatalities

Cessna 177 Cardinal CS-AKD Nose Gear Collapse at Espinho

Espinho, PT

On December 14, 1974, a Cessna 177 (registration CS-AKD) was involved in an aviation accident near Espinho, PT. No fatalities were reported. Investigators recorded the probable cause as: The aircraft collided with a ground vehicle on the runway during landing, causing the pilot to execute an emergency go-around at low altitude. The subsequent pull-up maneuver without adequate power management resulted in a stall and nose gear collapse. This summary draws on records from the Portuguese Office for the Prevention and Investigation of Accidents in Civil Aviation and Rail (GPIAAF).

Sourcesthe Portuguese Office for the Prevention and Investigation of Accidents in Civil Aviation and Rail (GPIAAF)Primary reportUpdated 2026-10-18Data APIEditorial standards

A Cessna 177 Cardinal collided with a vehicle on the runway at Espinho Aerodrome, causing the nose gear to collapse and the aircraft to veer off the pavement during landing.

What happened

On December 14, 1974, at approximately 16:10 local time, a Cessna 177 Cardinal (CS-AKD) belonging to the Aeroclube da Costa Verde was conducting a local sightseeing flight over Porto with three passengers. The aircraft returned to Espinho Aerodrome for landing on Runway 18 under clear weather conditions (CAVOK).

During the final approach, the pilot observed a cyclist crossing the runway. He executed a go-around to avoid the cyclist. Upon initiating the second approach, the pilot noticed a grey van emerging from the right side of the service road near the runway threshold. Instinctively pulling back on the controls to avoid a collision with the vehicle, the aircraft entered a stall at low altitude. The nose gear collapsed upon impact with the ground, causing the aircraft to veer off the asphalt. The pilot managed to keep the nose up to prevent a catastrophic capsize, though the aircraft sustained significant damage.

The investigation

The GPIAAF investigated the accident involving CS-AKD. The aircraft was a 1968 Cessna 177 Cardinal with 1,202 total flight hours. The pilot, aged 46, held a Private Pilot License and had flown the Cessna 177 in instruction or adaptation phases. He had 454.5 hours of visual flight time and 211 landings.

The aircraft was found to be airworthy prior to the incident. The maintenance report indicated that the nose gear was torn from its attachment plate, the propeller blades were bent inward beyond recovery limits, and the carburetor was severed from the engine mount due to the upward force of the gear collapse. The pilot reported no injuries, nor did the three passengers.

Findings

The primary cause was the collision with a ground vehicle on the active runway area, which forced an emergency maneuver at low altitude. Contributing factors included:

  • Pilot Error: The pilot reacted precipitously by pulling back on the controls without managing engine power, leading to a stall and subsequent nose gear collapse.
  • Aerodrome Safety: The Espinho Aerodrome lacked adequate security measures to prevent unauthorized or unmonitored vehicle movements in maneuvering areas. The presence of a van crossing the runway highlighted a critical safety gap for aeroclubs with less experienced users.

The GPIAAF concluded that while the pilot's reaction was understandable given the sudden threat, it resulted in a loss of control due to insufficient airspeed management. The investigation also noted that the lack of vehicle monitoring at the aerodrome was a significant hazard.

Safety action

The GPIAAF recommended an inquiry into the safety conditions of Espinho Aerodrome to ensure it met minimum security standards for opening traffic. They emphasized the need for better monitoring of vehicle movements in maneuvering areas, particularly on weekends when activity is high. Additionally, they suggested that the pilot undergo a proficiency check focusing on slow flight and stall recovery techniques.

Probable cause

The aircraft collided with a ground vehicle on the runway during landing, causing the pilot to execute an emergency go-around at low altitude. The subsequent pull-up maneuver without adequate power management resulted in a stall and nose gear collapse.

Frequently asked questions

What happened in the 14 Dec 1974 Cessna 177 accident near Espinho, PT?

A Cessna 177 Cardinal collided with a vehicle on the runway at Espinho Aerodrome, causing the nose gear to collapse and the aircraft to veer off the pavement during landing.

Were there any fatalities in the 14 Dec 1974 Cessna 177 accident?

No fatalities were recorded in this accident.

What aircraft was involved and where did it happen?

The accident on 14 Dec 1974 involved a Cessna 177, registration CS-AKD, at Espinho, PT.

What was the probable cause of the accident?

The aircraft collided with a ground vehicle on the runway during landing, causing the pilot to execute an emergency go-around at low altitude. The subsequent pull-up maneuver without adequate power management resulted in a stall and nose gear collapse.