Incident Details
During the takeoff roll, the propeller studs failed, causing the propeller to depart from the aircraft. The Federal Aviation Administration (FAA) incident report noted that the propeller had been overhauled and replaced 32 hours prior to the separation.
Investigation Findings
A metallurgical examination of the propeller studs revealed that the failure was due to fatigue. The fatigue cracks initiated through the threaded area of the studs, with no damage observed to the threads themselves. The fatigue failure occurred as a result of vibration caused by inadequate torquing of the mounting nuts.
The studs had been properly maintained according to the recent overhaul, but the improper torque allowed excessive movement and vibration, leading to crack initiation and propagation. The failure was confined to the studs, with no other structural issues identified.