On June 17, 1991, a Bowers Flybaby 1A (registration N8084D) operated by James H. Otterback was involved in an aviation accident near Stoughton, WI. Investigators recorded the probable cause as: THE INADEQUATE DESIGN BY THE MANUFACTURER TO PROVIDE FOR ADEQUATE PROTECTION FROM MOISTURE ACCUMULATION IN THE FORM OF DRAIN HOLES. CONTRIBUTING FACTORS WERE THE DETERIORATION (WOOD ROT) OF THE WING SPAR ATTACH AND THE LACK OF INSPECTION ACCESS. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.
During an aerobatic maneuver, the right wing separated from the airplane. The airplane descended into terrain. Investigation found wood rot at the fuselage carry-thru spar attachment and similar rot on the left side. No drain holes were present in that area.
Accident Description
While performing an aerobatic maneuver, the right wing failed and separated from the airplane. Subsequently, the airplane descended into the terrain.
Examination Findings
Post-accident examination revealed wood rot at the fuselage carry-thru spar attachment point, which was the location of the failure. Similar rot was discovered on the left side of the same attachment area. The examination also found that there were no drain holes in the area of the spar attachment where moisture could accumulate. Additionally, it was determined that the area where the deterioration occurred was not visible during normal inspections.
What happened in the 17 Jun 1991 Bowers Flybaby 1A accident near Stoughton, WI?
During an aerobatic maneuver, the right wing separated from the airplane. The airplane descended into terrain. Investigation found wood rot at the fuselage carry-thru spar attachment and similar rot on the left side. No drain holes were present in that area.
What aircraft was involved and where did it happen?
The accident on 17 Jun 1991 involved a Bowers Flybaby 1A, registration N8084D, operated by James H. Otterback, at Stoughton, WI.
What was the probable cause of the accident?
THE INADEQUATE DESIGN BY THE MANUFACTURER TO PROVIDE FOR ADEQUATE PROTECTION FROM MOISTURE ACCUMULATION IN THE FORM OF DRAIN HOLES. CONTRIBUTING FACTORS WERE THE DETERIORATION (WOOD ROT) OF THE WING SPAR ATTACH AND THE LACK OF INSPECTION ACCESS.
A SkyWalk Join't 3 paraglider crashed into the ground near Las Vizcachas, Chile, on September 1, 2024. The pilot and passenger sustained serious spinal…
PARAPENTE (ULTRALIVIANO NO MOTORIZADO)·2024-09-01DGAC Chile
A Cessna 172N struck electrical cables while on final approach to land at Aucó Aerodrome in Chile. The pilot was uninjured, but the aircraft sustained damage…
A Bombardier DHC-8-402 suffered a tail strike during landing at Puerto Williams on September 9, 2024. All 76 occupants were unharmed, but the aircraft…
A MYD JS-MD 3 glider veered off the runway and struck a wall at Vitacura Aerodrome on January 6, 2025. The pilot was uninjured, but the aircraft sustained…
A recreational paraglider flight in Puchuncaví, Chile, ended with the pilot sustaining serious injuries after a rapid descent and impact with a hillside on…
PARAPENTE (ULTRALIVIANO NO MOTORIZADO)·2025-03-29DGAC Chile
A Tecnam P2006T landed on its belly at an aerodrome in Poland after the crew failed to confirm landing gear deployment. The incident resulted in no injuries…