Casualties unknown

1992-04-12: Cessna 310-L (N331BX) — Bell, Anthony H. — Hugo, CO

Hugo, CO, US

On April 12, 1992, a Cessna 310-L (registration N331BX) operated by Bell, Anthony H. was involved in an aviation accident near Hugo, CO. Investigators recorded the probable cause as: The failure of the left voltage regulator, which caused an overvoltage and subsequent electrical fire, while the right alternator was inoperative. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 1781061362Data APIEditorial standards

A voltage regulator failure caused an overvoltage and electrical fire during cruise flight. The crew extinguished the fire and landed safely without communications or navigation equipment.

What happened

The aircraft was operating under instrument flight rules during a cruise phase of flight when a critical electrical system failure occurred. At the time of the incident, the right alternator was already inoperative, placing additional load on the remaining electrical components. The left voltage regulator subsequently failed, resulting in an overvoltage condition within the electrical system.

This electrical surge ignited a fire within the aircraft's systems. The crew successfully extinguished the fire, allowing them to continue the flight to their planned destination. However, the failure necessitated flying without the use of communications or navigation equipment for the remainder of the journey. Upon arrival, repairs were conducted to address the damage.

The investigation

The investigation focused on the sequence of electrical component failures that led to the fire. Examination confirmed that the left voltage regulator was the primary point of failure after the right alternator had already been removed from service. The overvoltage generated by this single regulator failure was identified as the direct cause of the ignition.

Findings

The contributing factors included the inoperative right alternator and the subsequent failure of the left voltage regulator. The lack of redundancy in the electrical system meant that a single point of failure resulted in a catastrophic overvoltage event. The crew's ability to extinguish the fire and navigate without standard equipment allowed for a safe landing, though the aircraft required significant repair upon arrival.

Probable cause

The failure of the left voltage regulator, which caused an overvoltage and subsequent electrical fire, while the right alternator was inoperative.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001211X14412. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.