Casualties unknown

Engine Power Loss After Fuel Tank Switch (N4836V)

Hayes Center, NE, US

On December 26, 1996, a Bellanca 17-30 (registration N4836V) was involved in an aviation accident near Hayes Center, NE. Investigators recorded the probable cause as: inadequate fuel management by the pilot, which resulted in fuel starvation. The factors relating to the accident were: a fuel leak at the engine driven fuel pump, and the engine driven fuel pump pressure was too low. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 2026-07-04Data APIEditorial standards

A pilot experienced an engine power loss about 50 minutes after switching to the left auxiliary fuel tank. The engine driven fuel pump had a leak and was below pressure limits. Restart attempts failed.

Incident Summary

A pilot reported a loss of engine power approximately 50 minutes after switching from the right auxiliary fuel tank to the left auxiliary tank. The pilot had flown for 35 minutes using the right auxiliary tank before making the switch. Following the power loss, the pilot attempted engine restart procedures but was unsuccessful.

Pilot Actions

The pilot stated that after the engine lost power, he performed the restart procedures as outlined in the Pilot Operating Handbook (POH). Despite these efforts, the engine could not be restarted.

Aircraft Systems

The aircraft was equipped with two auxiliary fuel tanks, each holding 17 gallons. The POH notes that if the fuel line runs dry, the boost pump must be activated to purge air from the line. The engine driven fuel pump was found to have a leak in the high pressure adjustment screw O-ring. Additionally, the fuel pump was operating below the required fuel pressure limit specified in the POH.

Fuel Management

The POH specifies a fuel consumption rate of 14 gallons per hour at 75 percent power at 6,500 feet mean sea level. The pilot managed the fuel supply by initially using the right auxiliary tank for 35 minutes, then switching to the left auxiliary tank. The subsequent power loss occurred about 50 minutes after the switch.

Frequently asked questions

What happened in the 26 Dec 1996 Bellanca 17-30 accident near Hayes Center, NE?

A pilot experienced an engine power loss about 50 minutes after switching to the left auxiliary fuel tank. The engine driven fuel pump had a leak and was below pressure limits. Restart attempts failed.

What aircraft was involved and where did it happen?

The accident on 26 Dec 1996 involved a Bellanca 17-30, registration N4836V, at Hayes Center, NE.

What was the probable cause of the accident?

inadequate fuel management by the pilot, which resulted in fuel starvation. The factors relating to the accident were: a fuel leak at the engine driven fuel pump, and the engine driven fuel pump pressure was too low.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001208X07146. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.