Casualties unknown

2002-01-18: Mbb BK-117 A-3 (N626MB) — CJ Systems Aviation Group, Inc — Cleveland, OH

Cleveland, OH, US

On January 18, 2002, a Mbb BK-117 A-3 (registration N626MB) operated by CJ Systems Aviation Group, Inc was involved in an aviation accident near Cleveland, OH. Investigators recorded the probable cause as: pilot's failure to maintain directional control of the helicopter while hovering, which resulted in its collision with a building. Factors were the confined area, tail wind, and wind gusts. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 1781061362Data APIEditorial standards

A medevac helicopter struck a building and fell approximately 13 floors after takeoff from a hospital rooftop helipad at night. The paramedic reported a sudden gust of wind pushed the helicopter close to the building.

Takeoff and Maneuver

The medevac helicopter lifted off from the hospital's rooftop helipad at night. During the departure, the pilot executed a right pedal turn to the northwest. This maneuver brought the helicopter facing a building that extended approximately 10 feet above the height of the helipad.

Proximity to Building

According to the paramedic, when the helicopter reached about 20 feet above the helipad, he was programming the GPS receiver. At that moment, a "sudden gust" of wind pushed the helicopter from directly behind. The paramedic stated he was not alerted to anything unusual until he looked up and noticed the helicopter's close proximity to a 16-floor brick building located at the northern corner of the heliport. This building extended above the helipad by 4 floors.

Avoidance Maneuver and Impact

The paramedic yelled "building, building, building!" to alert the pilot. In response, the pilot made a rapid right cyclic input in an attempt to avoid hitting the building. However, the helicopter struck the building and subsequently fell approximately 13 floors to ground level.

Paramedic's Observations

The paramedic reported that he did not see or hear any warning lights, horns, or unusual noises before the accident. He was not aware of any mechanical problems with the helicopter.

Wind Conditions

A police officer who had flown two missions in the local area prior to the accident reported that the wind speed at 500 feet above ground level was at least 25 knots and gusting from the south/southwest. After the accident, he stood on the primary helipad and noted that mechanical turbulence from the building was evident. An FAA inspector also stood on the rooftop helipad after the accident and stated that wind gusts were approximately 20-30 knots from the southwest, and they swirled around the heliport.

Flight Manual Limitations

Review of the helicopter flight manual revealed a limitation: "Directional controllability during take-off and landing is assured for flight condition with crosswind components up to 17 [knots]."

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20020131X00155. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.