Casualties unknown

Engine Failure Prompts Emergency Landing at Medical Center Parking Lot (N763DS)

Worcester, MA, US

On February 14, 1990, a Piper PA-28-181 (registration N763DS) operated by City Aviation was involved in an aviation accident near Worcester, MA. Investigators recorded the probable cause as: Oil pump failure due to overstress separation of the drive and driven impellers, leading to engine failure. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive; 4 related events involving the same aircraft type or operator are linked below.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 2026-07-04Data APIEditorial standards

During a night flight to Northampton, Massachusetts, an engine failure forced a pilot to land in a parking lot at UMass Medical Center in Worcester. The aircraft collided with a car and a utility pole. Investigation found the oil pump failed due to overstress separation of impellers.

Incident Overview

At night, while en route to Northampton, Massachusetts, the airplane experienced an engine failure. The pilot executed an emergency landing in the parking lot of the University of Massachusetts Medical Center in Worcester, Massachusetts. During the landing, the aircraft collided with a car and a utility pole. The collision with these objects could not have been avoided.

Engine Examination

Following the incident, an examination of the engine was conducted. The inspection revealed that the oil pump had failed. The connecting rods were found to be overtempered, and the bearings of the connecting rods had failed.

Oil Pump Analysis

A bench binocular microscopic examination was performed on the drive and driven impeller fracture surfaces of the oil pump. The analysis showed that the impellers broke as a result of overstress separations. The driven impeller exhibited characteristics typical of a sintered-powder-metal component. The total time on this component was 1,828.0 hours. The drive impeller appeared to be machined from barstock (steel).

Service Bulletin Compliance

Service Bulletin SB-456C specified a time of compliance at next overhaul, not to exceed 2,000 hours with sintered iron gears. The driven impeller, with 1,828 hours, was within this limit.

Probable cause

Oil pump failure due to overstress separation of the drive and driven impellers, leading to engine failure.

All Piper PA-28 Cherokee accidents →

Frequently asked questions

What happened in the 14 Feb 1990 Piper PA-28-181 accident near Worcester, MA?

During a night flight to Northampton, Massachusetts, an engine failure forced a pilot to land in a parking lot at UMass Medical Center in Worcester. The aircraft collided with a car and a utility pole. Investigation found the oil pump failed due to overstress separation of impellers.

What aircraft was involved and where did it happen?

The accident on 14 Feb 1990 involved a Piper PA-28-181, registration N763DS, operated by City Aviation, at Worcester, MA.

What was the probable cause of the accident?

Oil pump failure due to overstress separation of the drive and driven impellers, leading to engine failure.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001212X22623. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.