No fatalities

Cessna 172 Nose Gear Collapse Following Wind Gust During Landing Roll (N70397)

Greenville, TN, US

On April 15, 1993, a Cessna 172 (registration N70397) was involved in an aviation accident near Greenville, TN. No fatalities were reported. Investigators recorded the probable cause as: The pilot's improper procedures in that he landed with excessive flap extension, and his inadequate compensation for the gusting crosswind. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive; 1 related events involving the same aircraft type or operator are linked below.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 2026-07-04Data APIEditorial standards

A Cessna 172 experienced a strong wind gust during landing roll, causing it to balloon and drift right. The pilot attempted an abort but the nose gear broke off on impact, and the airplane collided with the airport perimeter fence.

Incident Overview

A Cessna 172 was involved in an accident during the landing rollout. According to the pilot, a strong wind gust caused the airplane to balloon back into the air and drift to the right side of the runway. The pilot attempted to abort the landing by adding power and applying full left rudder and aileron inputs. However, the airplane subsequently struck the ground, resulting in the nose gear breaking off. The aircraft continued and collided with the airport perimeter fence.

Sequence of Events

The accident occurred after the airplane touched down. During the landing roll, a gust of wind lifted the aircraft back into the air and pushed it to the right. The pilot responded by increasing engine power and using full left rudder and aileron in an effort to correct the trajectory. Despite these inputs, the airplane contacted the ground, causing the nose gear to separate. The aircraft then traveled beyond the runway surface and struck the perimeter fence.

Pilot Statement

The pilot reported that there were no mechanical malfunctions with the airplane. He stated that he had landed with the flaps fully extended. Prior to landing, he had requested advisories on the UNICOM frequency but was unable to understand the response. He also noted that before landing, he overflew the runway and observed the windsock indicating the wind was straight out and parallel to Runway 23.

Background

The Cessna 172 Pilot's Operating Handbook includes guidance that for landings in strong crosswinds, minimum flaps consistent with runway length should be used. The pilot had selected full flaps for the landing.

All Cessna 172 accidents →

Frequently asked questions

What happened in the 15 Apr 1993 Cessna 172 accident near Greenville, TN?

A Cessna 172 experienced a strong wind gust during landing roll, causing it to balloon and drift right. The pilot attempted an abort but the nose gear broke off on impact, and the airplane collided with the airport perimeter fence.

Were there any fatalities in the 15 Apr 1993 Cessna 172 accident?

No fatalities were recorded in this accident.

What aircraft was involved and where did it happen?

The accident on 15 Apr 1993 involved a Cessna 172, registration N70397, at Greenville, TN.

What was the probable cause of the accident?

The pilot's improper procedures in that he landed with excessive flap extension, and his inadequate compensation for the gusting crosswind.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001211X12066. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.