Casualties unknown

1997-11-20: Beech 95-B55 (N3681K) — Burlington, KS

Burlington, KS, US

On November 20, 1997, a Beech 95-B55 (registration N3681K) was involved in an aviation accident near Burlington, KS. Investigators recorded the probable cause as: an undetermined event resulting in the door seal inflation pump catching fire, the pilot's failure to close the cockpit air vents allowing heat and flames from the airplane's nose section to melt electrical wiring behind the instrument panel, and the pilot… This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 1781061362Data APIEditorial standards

A pilot reported a pneumatic door seal failure followed by electrical burning smell, smoke, and flames under the panel, leading to an emergency landing in a field after overshooting a dirt road.

Incident Overview

During a flight about 40 minutes after departure, a pilot and passenger heard the pneumatic door seal give way. The pilot recycled the switch but noted no change. A few minutes later, a faint smell of electrical burn was detected. The pilot turned off the heater, and the smell subsided. Upon reactivating the heater, the smell returned immediately, stronger than before. Black smoke then began entering the cabin from above and beneath the instrument panel. The pilot observed orange sparks and flames under the panel.

Emergency Descent and Landing

The pilot initiated a steep descent and searched for a landing site. Spotting a north-south oriented dirt road, the pilot executed a 180-degree turn to land. However, the aircraft overshot the road, and the pilot determined insufficient altitude and airspeed to maneuver back. The pilot leveled the airplane and landed in a field. During the landing roll, the aircraft encountered uneven rising terrain and trees.

Post-Incident Examination

An examination of the aircraft revealed that the door seal inflation pump was heavily charred. Inspection of the cabin showed the door inflation seal around the cabin door was missing. Both forward air vents were found in the open position. Plastic insulation surrounding electrical wiring in front of the right air vent was melted. Melted plastic was observed on the floor beneath the right side air vent. No other anomalies were identified.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20001208X09151. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.