Casualties unknown

2004-08-18: Cessna 750 (N961QS) — Jackson, WY

Jackson, WY, US

On August 18, 2004, a Cessna 750 (registration N961QS) was involved in an aviation accident near Jackson, WY. Investigators recorded the probable cause as: The failure occurred due to fatigue cracking initiated by an undetected manufacturing defect from electrical arcing that produced physical craters on the interior surface of the trailing link and locally changed the microstructure. This summary draws on records from the U.S. National Transportation Safety Board (NTSB) historical archive; 7 related events involving the same aircraft type or operator are linked below.

Sourcesthe U.S. National Transportation Safety Board (NTSB) historical archivePrimary reportUpdated 1781061362Data APIEditorial standards

During landing roll at low speed, the right main landing gear failed. Examination revealed fatigue cracking from an undetected manufacturing defect caused by electrical arcing.

Incident Overview

During the landing roll at a speed of approximately 10 to 15 miles per hour, the right main landing gear failed, causing the airplane to come to a stop on a taxiway. The failure resulted in the separation of the right main landing gear trailing link and wheel assembly from the aircraft. A portion of the upper trailing link and axle assembly remained attached to the main trunnion.

Landing Gear History

At the time of the incident, the landing gear assembly had accumulated 5,228.5 total flight hours and 3,358 total cycles since new. The trailing link and axle assembly was certified for a service life of 44,400 total cycles.

Metallurgical Examination

A metallurgical examination of the right main landing gear trailing link determined that the failure was due to fatigue cracking. This cracking was initiated by an undetected manufacturing defect. The defect originated from electrical arcing, which produced physical craters on the interior surface of the trailing link and locally altered the microstructure of the material.

Manufacturing Defect Details

The craters and the changed microstructure acted as stress concentrators, which, under the influence of cyclic stresses, would initiate fatigue cracks. The defects were covered by cadmium plating and primer paint. The presence of cadmium plating established that the damage had occurred prior to or during the early stages of the plating process during manufacture.

Probable cause

The failure occurred due to fatigue cracking initiated by an undetected manufacturing defect from electrical arcing that produced physical craters on the interior surface of the trailing link and locally changed the microstructure.

Investigation report by the U.S. National Transportation Safety Board (NTSB) historical archive. Original record: https://carol.ntsb.gov/event/20040831X01326. This page is a structured re-presentation; facts and quotes are in the National Transportation Safety Board (NTSB), United States.